Meters

MGI-50 · PULSER 52 litres x pulse · ±0,5%
 
Liquids: Diesel Diesel  Lubricant Lubricant  
MGI-50 · Pulser

Pulser for its in-line assembly, making esier the exact information of the fluid management and control systems.

 

Technical data:

  • Flow: 4-50 l/min
  • Voltage: 28VCA/VCC
  • Maximum current: 100mA
  • Accuracy: ±0,5%
  • Maximum security pressure: 120bar
  • Maximum operation pressure: 70bar
  • Min./max. temperature: -10ºC / +60ºC
  • Two communication channels through REEDS
  • Pulses: 2 dephased channels at 180°
  • Housing and cover: Aluminium
  • Pulses per channel: 52 pulses/l
  • Connection: F3/4" (flange)
Size and weight (approx.):
  • Size: 153x90x105mm (length x width x height)
  • Weight: 1,95Kg
MGI-50 · PULSER