USE
- GENIUS is a level monitor in atmospheric tanks.
- The level measurement is made by measuring the static pressure of the liquid height through a tube into the tank.
- It allows measuring the level in rectangular and cylindrical, horizontal or vertical, tanks with a maximum height of 4m.
- Accuracy: ±1%
COMPOSED OF
- Probe with 10 metres of tube (extending at 50m) of 6mm and with a weight in the other end that is immersed in the liquid till touching the bottom.
- Max. tube length: 50m
- Control unit to see the liquid level and configuration
- Two outlets to connect two alarm or control devices
Configuration of:
- Tank type and dimensions, calibration
- Level alarms
- Level reading type
- Measuring unit
- According to the programmed alarm levels, the control unit will activate or deactivate the contacts, acting as a remote switch for the alarm device operation or the connected control kits operation.
- PC communication kit through the RS-485 communication port
- Connection to PC or GK-7 controller or similar
* It is not suitable for flammable or explosive liquids